The armature is an important part of tributary electric motor and single-phase series motor, and its common faults include winding grounding, short circuit and reversed connection. These can be detected with a multimeter and megger. As shown in figure, it is a test schematic diagram with traffic light. When it is measured, the black stick of light is connected to the shaft ( ground ), red bar table is touched commutator segment. If the lamp H is not bright, it means that there is not a pathway between winding or commutator and shaft, no ground fault. If the light bulb is lit, it has existed ground fault and should be promptly repaired.