SLA24C32-D, SLA24C32S, SLA24C64D Selling Leads, Datasheet
MFG:DIP Package Cooled:1998 D/C:1999
SLA24C32-D, SLA24C32S, SLA24C64D Datasheet download
Part Number: SLA24C32-D
MFG: DIP
Package Cooled: 1998
D/C: 1999
MFG:DIP Package Cooled:1998 D/C:1999
SLA24C32-D, SLA24C32S, SLA24C64D Datasheet download
MFG: DIP
Package Cooled: 1998
D/C: 1999
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: SLA24C32-D
File Size: 366431 KB
Manufacturer: SIEMENS [Siemens Semiconductor Group]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: SLA0201
File Size: 33205 KB
Manufacturer: SANKEN [Sanken electric]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: SLA0201
File Size: 33205 KB
Manufacturer: SANKEN [Sanken electric]
Download : Click here to Download
The SLx 24C32 device is a serial electrically erasable and programmable read only memory (EEPROM), organized as 4096 ´ 8 bit. The data memory is divided into 128 pages. The 32 bytes of a page can be programmed simultaneously.
The device conforms to the specification of the 2-wire serial I2C-Bus. Three chip select pins allow the addressing of 8 devices on the I2C-Bus. Low voltage design permits operation down to 2.7 V with low active and standby currents. All devices have a minimum endurance of 106 erase/write cycles1).
The device operates at 5.0 V ± 10% with a maximum clock frequency of 400 kHz and at 2.7 ... 5.5 V with a maximum clock frequency of 100 kHz. The device with a voltage range of 2.7 . 5.5. V is available in two temperature ranges for industrial and automotive applications. The EEPROMs are mounted in eight-pin DIP and DSO packages or are also supplied as chips.
Stresses above those listed here may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational section of this data sheet is not implied.Exposure to absolute maximum ratings for extended periods may affect device reliability.
Parameter |
Limit Values |
Unit |
Operating temperature range 1 (industrial) range 2 (automotive) |
40 to + 85 40 to + 125 |
°C °C |
Storage temperature |
65 to + 150 |
°C |
Supply voltage |
0.3 to + 7.0 |
V |
All inputs and outputs with respect to ground |
0.3 to VCC + 0.5 |
V |
ESD protection (human body model) |
4000 |
V |