AD25S0AHD, AD26, AD260 Selling Leads, Datasheet
MFG:AD Package Cooled:SMD-20 D/C:05+
AD25S0AHD, AD26, AD260 Datasheet download

Part Number: AD25S0AHD
MFG: AD
Package Cooled: SMD-20
D/C: 05+
MFG:AD Package Cooled:SMD-20 D/C:05+
AD25S0AHD, AD26, AD260 Datasheet download

MFG: AD
Package Cooled: SMD-20
D/C: 05+
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: AD202
File Size: 422810 KB
Manufacturer: AD [Analog Devices]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: AD260
File Size: 168503 KB
Manufacturer: AD [Analog Devices]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: AD260
File Size: 168503 KB
Manufacturer: AD [Analog Devices]
Download : Click here to Download
The AD260 is designed using Analog Devices new IsoLogic circuit architecture to isolate five digital control signals to/ from a microcontroller and its related field I/O components. Six models allow all I/O combinations from five input lines to five output lines, including combinations in between. Every AD260 effectively replaces up to five opto-isolators while also providing the 1.5 W transformer for a 3.5 kV isolated dc-dc power supply circuit.
Each line of the AD260 has a bandwidth of 20 MHz (min) with a propagation delay of only 14 ns, which allows for extremely fast data transmission. Output waveform symmetry is maintained to within ±1 ns of the input so the AD260 can be used to accurately isolate time-based PWM signals.
All field or system output pins of the AD260 can be set to a high resistance three-state level by use of the two enable pins. A field output three-stated offers a convenient method of presetting logic levels at power-up by use of pull-up/down resistors. System side outputs being three-stated allows for easy multiplexing of multiple AD260s.
| Parameter | Conditions | Min Typ Max | Units |
| Supply Voltage (+5 V dcSYS & FLD) DC Input Voltage (VIN MAX) DC Output Voltage (VOUT MAX) Clamp Diode Input Current (IIK) Clamp Diode Output Current (IOK) Output DC Current, per Pin (IOUT) DC Current, VCC or GND (ICC or IGND) Storage Temperature (TSTG) Lead Temperature (Soldering, 10 sec) Electrostatic Protection (VESD) |
Referred to +5 V dcSYS & FLD and 5 V RTNSYS & FLD Respectively Referred to +5 V RTNSYS & FLD and 5 V dcSYS & FLD Respectively For VI < 0.5 V or VI > 5 V RTNSYS & FLD +0.5 V For VO < 0.5 V or VO > 5 V RTNSYS & FLD +0.5 V Per MIL-STD-883, Method 3015 |
0.5 +6.0 0.5 +0.5 0.5 +0.5 25 +25 25 +25 25 +25 50 +50 40 +85 +300 4.5 5 |
V |