UG10FCT, UG10FT, UG10GCT Selling Leads, Datasheet
MFG:GS Package Cooled:TO D/C:05+
UG10FCT, UG10FT, UG10GCT Datasheet download

Part Number: UG10FCT
MFG: GS
Package Cooled: TO
D/C: 05+
MFG:GS Package Cooled:TO D/C:05+
UG10FCT, UG10FT, UG10GCT Datasheet download

MFG: GS
Package Cooled: TO
D/C: 05+
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: UG10FCT
File Size: 52484 KB
Manufacturer: GE [General Semiconductor]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: UG1
File Size: 36693 KB
Manufacturer:
Download : Click here to Download
PDF/DataSheet Download
Datasheet: UG10GCT
File Size: 52484 KB
Manufacturer: VISAY [Vishay Siliconix]
Download : Click here to Download
|
SYMBOLS |
UG10FCT |
UG10GCT |
UNITS | |
| Maximum repetitive peak reverse voltage |
VRRM |
300 |
400 |
Volts |
| Working peak reverse voltage |
VRWM |
225 |
300 |
|
| Maximum RMS voltage |
VRMS |
210 |
280 |
Volts |
| Maximum DC blocking voltage |
VDC |
300 |
400 |
Volts |
| Maximum average forward rectified currentat TL=105°C |
I(AV) |
10 |
Amps | |
| Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load (JEDEC Method) PER LEG |
IFSM |
60A |
Amps | |
| Maximum instantaneous forward voltage per leg TJ=25°C (NOTE 1) IF= 5A TJ=150°C |
VF |
1.30 1.05 |
Volts | |
| Maximum reverse leakage current TJ=25°C at working peak reverse voltage TJ=100°C |
IR |
10 200 |
A | |
| Maximum reverse recovery time per leg at IF=0.5A, IR=1.0A, Irr=0.25A |
trr |
35 |
ns | |
| Maximum Reverse recovery time per leg at IF=1.0A, di/dt=100A/ms, VR=30V, Irr=0.1 IRM |
trr |
50 |
ns | |
| Maximum reverse recovery current per leg at IF=5A, di/dt=50A/ms,VR=30V TC=100°C |
Qrr |
3.0 |
nC | |
| Maximum stored charge per leg IF=2A, di/dt=20A/ms, VR=30V, Irr=0.1 IRM |
CJ |
50 |
pF | |
| Typical thermal resistance from junction to case per leg |
RQJC |
4.5 |
°C/W | |
| Operating junction and storage temperature range |
TJ, TSTG |
-45to+150 |
°C | |
|
SYMBOLS |
UG10FCT |
UG10GCT |
UNITS | |
| Maximum repetitive peak reverse voltage |
VRRM |
300 |
400 |
Volts |
| Working peak reverse voltage |
VRWM |
225 |
300 |
|
| Maximum RMS voltage |
VRMS |
210 |
280 |
Volts |
| Maximum DC blocking voltage |
VDC |
300 |
400 |
Volts |
| Maximum average forward rectified currentat TL=105°C |
I(AV) |
10 |
Amps | |
| Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load (JEDEC Method) PER LEG |
IFSM |
60A |
Amps | |
| Maximum instantaneous forward voltage per leg TJ=25°C (NOTE 1) IF= 5A TJ=150°C |
VF |
1.30 1.05 |
Volts | |
| Maximum reverse leakage current TJ=25°C at working peak reverse voltage TJ=100°C |
IR |
10 200 |
A | |
| Maximum reverse recovery time per leg at IF=0.5A, IR=1.0A, Irr=0.25A |
trr |
35 |
ns | |
| Maximum Reverse recovery time per leg at IF=1.0A, di/dt=100A/ms, VR=30V, Irr=0.1 IRM |
trr |
50 |
ns | |
| Maximum reverse recovery current per leg at IF=5A, di/dt=50A/ms,VR=30V TC=100°C |
Qrr |
3.0 |
nC | |
| Maximum stored charge per leg IF=2A, di/dt=20A/ms, VR=30V, Irr=0.1 IRM |
CJ |
50 |
pF | |
| Typical thermal resistance from junction to case per leg |
RQJC |
4.5 |
°C/W | |
| Operating junction and storage temperature range |
TJ, TSTG |
-45to+150 |
°C | |