Purchase 2322 691 90001, In-stock 2322 691 90001 From SeekIC.


Part Number: 2322 691 90001
Description: This capacitive atmospheric humidity sensor consists of a non-conductive foil, which is covered on bot...


Description: This capacitive atmospheric humidity sensor consists of a non-conductive foil, which is covered on bot...
This capacitive atmospheric humidity sensor consists of a non-conductive foil, which is covered on both sides with a layer of gold. The dielectric constant of the foil changes as a function of the relative humidity of the ambient atmosphere and, accordingly, the capacitance value of the sensor is a measure for relative humidity. The foil is clamped between contact springs and assembled in a plastic housing. It is provided with two connecting pins which fit printed-circuit boards with a grid pitch of 2.54 mm, provision is also made for fastening with 3 mm bolts. The characteristics are not affected by incidental water condensation on the sensor foil. It should not be exposed to either acetone or chlorine vapours.
| PARAMETER |
VALUE |
UNIT |
| Humidity range (RH) |
10 to 90 |
% |
| Tanat +25°C; 100 kHz; 43% RH |
0.035 |
PF |
| Sensitivity between 12 and 75% RH |
0.4±0.05 |
PF/%R |
| Frequency |
1 to 1000 |
kHz |
| Temperature dependence |
0.1 |
%RH/K |
| Response time in minutes (to 90% of indicated RH change at +25°C, in circulating air): between 10 and 43% RH between 43 and 90% RH |
<3 |
|
|
<5 | ||
| Hysteresis (for RH excursion of 10 to 90 to 10%) |
3 |
% |
| Maximum AC or DC voltage |
15 |
V |
| Storage humidity range (RH) |
0 to 100 |
% |
| Ambient temperature range: operating storage |
0 to +85 |
° C |
|
−25 to +8 |
° C | |
| Drop test: height of free fall |
1 |
M |
| Mass |
1.3 |
G |
Note
Unless otherwise stated, measurements are in accordance with"IEC publication 60539".
Stability is in accordance with"CECC 43000"and"IEC 60068-2".
•Humidity measurements in electronic hygrometers for domestic use
•Self-regulating air humidifiers, etc.
23220