Triacs RAIL TRIAC
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
| Rated Repetitive Off-State Voltage VDRM : | 600 V | Off-State Leakage Current @ VDRM IDRM : | 0.5 mA | ||
| Gate Trigger Voltage (Vgt) : | 1.5 V | Gate Trigger Current (Igt) : | 5 mA | ||
| Holding Current (Ih Max) : | 15 mA | Mounting Style : | Through Hole | ||
| Package / Case : | TO-220AB | Packaging : | Rail |

| SYMBOL | PARAMETER | CONDITIONS | MIN. | MAX. | UNIT |
| VDRM | Repetitive peak off-state voltages | - | 600 | V | |
| IT(RMS) | RMS on-state current | full sine wave;Tmb 99 ˚C | - | 16 | A |
| ITSM | Non-repetitive peak on-state current | full sine wave; Tj = 25 ˚C prior to surge t = 20 ms t = 16.7 ms |
- - |
140 150 |
A A |
| I2t | I2t for fusing | t = 10 ms | - | 98 | A2s |
| dIT/dt | Repetitive rate of rise of on-state current after triggering | ITM = 12 A; IG = 0.2 A; dIG/dt =0.2 A/µs |
- |
100 | A/µs |
| IGM | Peak gate current | over any 20 ms period | - | 2 | A |
| PGM | Peak gate power | - | 5 | W | |
| PG(AV) | Average gate power | - | 0.5 | W | |
| Tstg | Storage temperature | -40 | 150 | ˚C | |
| Tj | Operating junction temperature | - | 125 | ˚C |
Passivated guaranteed commutationtriacs BTA216-600D in a plastic envelope intended for use in motor control circuits or with other highly inductive loads. BTA216-600D balance the requirements of commutation performance and gate sensitivity. The "sensitive gate" E series and "logic level" D series are intended for interfacing with low power drivers, including micro controllers.