Purchase CD54A, In-stock CD54A From SeekIC.


Part Number: CD54A
Description: The 'AC05 devices contain six independent inverters. These devices perform the Boolean function Y = A....


Description: The 'AC05 devices contain six independent inverters. These devices perform the Boolean function Y = A....
The 'AC05 devices contain six independent inverters. These devices perform the Boolean function Y = A. The open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain outputs to implement active-low wired-OR or active-high wired-AND functions.
Supply voltage range, Vcc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.5 V to 6 V
Input clamp current, Iik (Vi < 0 or Vi> V cc) (see Note 1) . . . . . . . . . . . ± 20 mA
Output clamp current, Iok (Vo < 0 or Vo > Vcc ) (see Note 1) . . . . . . . ± 50 mA
Continuous output current, Io (Vo = 0 to Vcc ) . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through V cc or GND . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Package thermal impedance, JA (see Note 2): E package . . . . . . . . . 80°C/W
M package . . . . . . . . . 86°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . .65°C to 150°C
AC Types Feature 1.5-V to 5.5-V Operation and Balanced Noise Immunity at 30% of the Supply Voltage
Speed of Bipolar F, AS, and S, With Significantly Reduced Power Consumption
Balanced Propagation Delays
±24-mA Output Drive CurrentFanout to 15 F Devices
SCR-Latchup-Resistant CMOS Process and Circuit Design
Exceeds 2-kV ESD Protection Per MIL-STD-883, Method 3015