Features: 300 Watts Peak Pulse Power (tp = 8x20us) Transient Protection for data, signal, and VCCbus to IEC61000-4-2 level 4 (ESD) and IEC61000-4-4 (EFT) Low Capacitance, typ. <2 pF Low Leakage Current Unidirectional Configuration Surface Mount Package Ideally Suited forAutomatic InsertionSpeci...
DLP05LC: Features: 300 Watts Peak Pulse Power (tp = 8x20us) Transient Protection for data, signal, and VCCbus to IEC61000-4-2 level 4 (ESD) and IEC61000-4-4 (EFT) Low Capacitance, typ. <2 pF Low Leakage C...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
300 Watts Peak Pulse Power (tp = 8x20us)
Transient Protection for data, signal, and VCCbus to IEC61000-4-2 level 4 (ESD) and IEC61000-4-4 (EFT)
Low Capacitance, typ. <2 pF
Low Leakage Current
Unidirectional Configuration
Surface Mount Package Ideally Suited forAutomatic Insertion
| Part Number | DLP05LC |
| Power Rating (W) | 300 |
| Reverse Standoff Voltage VRWM (V) | 5 |
| Breakdown Voltage VBR Min | 6 |
| Breakdown Voltage VBR Max | - |
| Max Reverse Leakage Current IR @ VRWM Max (µA) | 20 |
| Max Clamping Voltage @ Max Peak Pulse Current VC (V) | 11 |
|
Characteristic |
Symbol |
Value |
Unit |
|
Peak Pulse Power (tp = 8x20us) |
Ppk |
300 |
W |
|
Thermal Resistance, Junction to Ambient |
RJA |
286 |
/W |
|
Operating and Storage and Temperature Range |
Tj,TSTG |
-55 to +150 |