Specifications Module Specifications Pneumatic Outputs Outputs per Module 11 (grouped) Thermal Derating Refer to Table 2 Supply Pressure 100 psi max. Pressure Drop 25 psi max.@ 0.25scfm External Solenoid Power 21.6-26.4VDC, 24VDC nominal Isolation 1500 volts bet...
IC693MDL760: Specifications Module Specifications Pneumatic Outputs Outputs per Module 11 (grouped) Thermal Derating Refer to Table 2 Supply Pressure 100 psi max. Pressure Drop 25 psi...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Module Specifications | |
Pneumatic Outputs | |
Outputs per Module |
11 (grouped) |
Thermal Derating | Refer to Table 2 |
Supply Pressure |
100 psi max. |
Pressure Drop | 25 psi max.@ 0.25scfm |
External Solenoid Power |
21.6-26.4VDC, 24VDC nominal |
Isolation | 1500 volts between field side and logic side; 500 volts between groups |
Solenoid Inrush Current |
33mA/valve @ 24VDC |
Solenoid Holding Current | 13mA/valve @ 24VDC |
ON Response Time |
12ms max. |
OFF Response Time | 12ms max. |
Maximum Solenoid ON Time |
30 days max. (must be turned OFF at least once every 30 days) |
Output Fitting | Threaded for 10-32 adapter, 1/16 hose barb provided |
Supply Fitting |
Threaded for 10-32 adapter, 1/8 hose barb provided |
LED Indicators for output points | One LED per output point indicates ON/OFF state |
LED "PWR" Indicator | LED indicates solenoid power is present |
DC Outputs |
|
Outputs per Module | 5 (grouped) |
Thermal Derating |
None |
Output Voltage | 18-30VDC, 24VDC nominal |
Isolation |
1500 volts between field side and logic side; 500 volts between groups |
Continuous Load Current | 0.5A @ 30VDC per point, 2.0A total for all five points |
Inrush Current |
2.0A for 100ms |
Voltage Drop | 0.5V max |
Leakage Current |
1mA @ 30VDC max |
ON Response Time | 2ms max. |
OFF Response Time |
2ms max. |
Protection (each output) | No internal fuse |
LED Indicators | One LED per output shows on/off state |
Module Characteristics |
|
Operational Ambient Temperature |
45°C (113° F) max. |
Backplane Current | 75mA from 5V bus (solenoid LEDs are powered from external power source) |
This IC693MDL760 output module provides eleven pneumatic outputs and five 24VDC sourcing outputs. For each pneumatic output, the module contains an internal 3- way solenoid-actuated valve and an associated output fitting, which is located on the front panel. When an output is turned ON, its internal valve connects a usersupplied pressure source (100 psi maximum) to the output fitting. The pressure source is connected to the fitting on the bottom of the module. When the output is turned OFF, the valve's output port is vented to atmosphere inside the module. Solenoid power is supplied from an external 24VDC source to the "DC Outputs" connector on the front panel.
A 12-pin connector of the IC693MDL760, located on the module's front panel, allows the user to connect the optional IC693ACC760 Solenoid Forcing Pendent, described later.
The five IC693MDL760outputs can each drive up to a maximum 0.5A, with a limit of 2.0A total for all five points. Field wiring is connected to these outputs via a 10-pin connector located on the front panel. The user must provide 24VDC to this connector to power the positive logic outputs, which source current to the field
connections. This group of five discrete outputs is electrically isolated from the PLC backplane; however, the outputs are not individually isolated from each other.
The IC693MDL760 module is accessed from the logic program as a standard 16-point output module. When using VersaPro version 2.0 (or later version) programming software, it should be configured by its catalog number. When using programming software other than VersaPro version 2.0 (or later version), the module must be configured as a standard 16-point generic output module.
The IC693MDL760 module is enclosed in a standard IC693 plastic housing.