Features: • Full wave current sensing• Mains supply variation compensated• Programmable load-current limitation with over- and high-load output• Variable soft-start• Voltage and current synchronization• Automatic retriggering switchable• Triggering pulse t...
IL2010B: Features: • Full wave current sensing• Mains supply variation compensated• Programmable load-current limitation with over- and high-load output• Variable soft-start• Vo...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
• Full wave current sensing
• Mains supply variation compensated
• Programmable load-current limitation with over- and high-load output
• Variable soft-start
• Voltage and current synchronization
• Automatic retriggering switchable
• Triggering pulse typical 125 mA
• Internal supply voltage monitoring
• Current requirement 3 mA
• Temperature compensated reference voltage

| Parameters | Pin | Symbol | Value | Unit |
| Sink current t 10us |
11 | IS | 300 | mA |
| is | 100 | |||
| Sync. currents t 10us |
15 | ±IsyncV | 5 | mA |
| ±isyncV | 20 | |||
| Phase control | ||||
| Control voltage | 4 and 8 | V | 0 V8 | V |
| Input current | 4 | ± II | 500 | uA |
| Charging current | 14 | I max | 0.5 | mA |
| Soft-start | ||||
| Input voltage | 7 and 8 | VI | 0 V8 | V |
| Pulse output | ||||
| Input voltage | 16 | +VI | 2 | V |
| VI | V11 | |||
| Reference voltage source | ||||
| Output currentt 10us |
8 | I0 | 10 | mA |
| i0 | 30 | mA | ||
| Load current sensing | ||||
| Input currents | 1 and 2 | ± Ii | 1 | mA |
| Input voltages | 5 and 6 | Vi | 0 V8 | V |
| Overload output | 13 | IL | 1 | mA |
| High-load outputt 10us |
12 | IL | 30 | mA |
| IL | 100 | mA | ||
| Storage temperature range | Tstg | -40 to +125 | ||
| Junction temperature range | Tj | 125 | ||
| Ambient temperature range | Tamb | -10 to +100 | ||
The IL2010B is designed as a phase-control circuit in bipolar technology. It enables loadcurrent detection and has a soft-start function as well as reference voltage output. Motor control with load-current feedback and overload protection are preferred applications.