LNK362 General Description
LNK362 Maximum Ratings
DRAIN Voltage .................................. .............-0.3 V to 700 V
Peak DRAIN Current: LNK362..........................200 mA (375 mA)(2)
LNK363/364..................400 mA (750 mA)(2)
FEEDBACK Voltage ........................................ -0.3 V to 9 V
FEEDBACK Current .........................................100 mA
BYPASS Voltage............................................. -0.3 V to 9 V
Storage Temperature ....................................-65 °C to 150 °C
Operating Junction Temperature(3) ...............-40 °C to 150 °C
Lead Temperature(4) ................................... 260 °C
LNK362 Features
• Accurate hysteretic thermal shutdown protection automatic recovery improves fi eld reliability
• Universal input range allows worldwide operation
• Simple ON/OFF control, no loop compensation needed
• Eliminates bias winding simpler, lower cost transformer
• Very low component count higher reliability and single side printed circuit board
• Auto-restart reduces delivered power by 95% during short circuit and open loop fault conditions
• High bandwidth provides fast turn on with no overshoot and excellent transient load response
LNK362 Typical Application
• Chargers/adapters for cell/cordless phones, PDAs, digital cameras, MP3/portable audio players, and shavers
• Supplies for appliances, industrial systems, and metering
LNK362 Connection Diagram