MFG:PHILIPS

Drain to Source Voltage. . . . . . . . . . . . . . . . . . . . . . . . . 30V
Gate to Drain Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 30V
Drain Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50mA
Gate Zener Current . . . . . . . . . . . . . . . . . . . . . . . . .±0.1mA
Storage Temperature Range . . . . . . . . . . . .-65 to +200
Operating Temperature Range . . . . . . . . . . . -55 to +12
Lead Temperature (Soldering, 10sec) . . . . . . . . . . .. +300
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . 225mW
Derate above 25 . . . . . . . . . . . . . . . . . . . . . . ...2.2mW/
NOTE: Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions above those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.