Purchase MAX4198, In-stock MAX4198 From SeekIC.


Part Number: MAX4198
Description: The MAX4198/MAX4199 low-power, Rail-to-Rail® differential amplifiers are ideal for single-supply a...


Description: The MAX4198/MAX4199 low-power, Rail-to-Rail® differential amplifiers are ideal for single-supply a...
The MAX4198/MAX4199 low-power, Rail-to-Rail® differential amplifiers are ideal for single-supply applications that benefit from a low 0.01% gain error. The MAX4198 is factory trimmed to a fixed gain of +1V/V, and the MAX4199 is trimmed to a fixed gain of +10V/V. Capable of operating from a single +2.7V to +7.5V supply or from dual ±1.35V to ±3.75V supplies, they consume only 42µA while achieving -3dB bandwidths of 175kHz (MAX4198) and 45kHz (MAX4199). These amplifiers feature a shutdown mode that reduces the supply current to 6.5µA.
The MAX4198/MAX4199 can drive 5k½ loads to within 100mV from each rail. The standard differential amplifier configurations provide common-mode rejection of 90dB for the MAX4198 and 110dB for the MAX4199. The input common-mode voltage range for the MAX4198 extends 100mV Beyond-the-Rails™.
The MAX4198/MAX4199 are offered in a space-saving 8-pin µMAX package. For complete micropower, rail-torail instrumentation amplifiers, see the MAX4194 MAX4197 data sheet.
Supply Voltage (VCC to VEE)..............................................................+8V
All Other Pins to GND ..................................(VEE - 0.3V) to (VCC + 0.3V)
Output Short Circuit Duration (to VCC or VEE).......................Continuous
Continuous Power Dissipation (TA = +70°C)
SO (derate 9.09mW/°C above +70°C)....................................471mW
µMAX (derate 4.1mW/°C above +70°C) .................................330mW
Operating Temperature Range ..................................-40°C to +85°C
Junction Temperature...............................................................+150°C
Storage Temperature Range .................................. -65°C to +150°C
Lead Temperature (soldering, 10sec) .....................................+300°C
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.