Specifications PARAMETERS/TEST CONDITIONS SYMBOL LIMITS UNITS Gate-Source Voltage VGS ±12 V Continuous Drain Current TC = 25 °C ID 12 A TC = 100 °C 8 Pulsed Drain Current1 IDM 45 Avalanche Energy L = 0.1mH EAS 60 mJ Repetitive A...
P3056LS: Specifications PARAMETERS/TEST CONDITIONS SYMBOL LIMITS UNITS Gate-Source Voltage VGS ±12 V Continuous Drain Current TC = 25 °C ID 12 A TC = 100 °C 8 ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
| PARAMETERS/TEST CONDITIONS |
SYMBOL |
LIMITS |
UNITS | |
| Gate-Source Voltage |
VGS |
±12 |
V | |
| Continuous Drain Current | TC = 25 °C |
ID |
12 |
A |
| TC = 100 °C |
8 | |||
| Pulsed Drain Current1 |
IDM |
45 | ||
| Avalanche Energy | L = 0.1mH |
EAS |
60 |
mJ |
| Repetitive Avalanche Energy2 | L = 0.05mH |
EAR |
3 | |
| Power Dissipation | TC = 25 °C |
PD |
43 |
W |
| TC = 100 °C |
15 | |||
| Operating Junction & Storage Temperature Range |
Tj, Tstg |
-55 to 150 |
°C | |
| Lead Temperature (1/16" from case for 10 sec.) |
TL |
275 | ||