Features: · Designed for Front-End of RF Detector· Simple External Impedance Matching· Hermetic TO39-3 Case· Unbalanced Input and OutputSpecifications Rating Value Units Maximum Incident Power in Passband +10 dBm Max. DC voltage between any 2 terminals 30 VDC Storage Temperatur...
RF1046: Features: · Designed for Front-End of RF Detector· Simple External Impedance Matching· Hermetic TO39-3 Case· Unbalanced Input and OutputSpecifications Rating Value Units Maximum Incident P...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
| Rating | Value | Units |
| Maximum Incident Power in Passband | +10 | dBm |
| Max. DC voltage between any 2 terminals | 30 | VDC |
| Storage Temperature Range | -55 to +85 | °C |
| Max Soldering Profile | 265°C for 10 s | |
Notes:
1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified
demonstration board with impedance matching to 50 W and measured with 50 W network analyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent
on PCB layout and external impedance matching design. See Application Note No. 42 for details. All "NC" or "no connection"
terminals should be grounded.
4. "LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E" indicates "engineering prototypes."
5. The design, manufacturing process, and specifications of this filter are subject to change.
6. Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may
vary between Port 1 and Port 2, so that the filter must always be installed in one direction per the circuit design.
7. US and international patents may apply.
8. RFM, stylized RFM logo, and RF Monolithics, Inc. are registered trademarks of RF Monolithics, Inc.
9. ãCopyright 1999, RF Monolithics Inc.
10. Electrostatic Sensitive Device. Observe precautions for handling.