Features: EN 60950 certified, rated for 250VAC UL-60950-1 / CSA C22.2 certified 5.2kVDC Isolation for 1 Minute Optional Continuous Short Circuit Protected Wide Temperature Performance at full 1 Watt Load, 40°C to +85°C 2 Chamber Transformer System UL94V-0 Package Material Efficiency to 80%Specif...
RxxP3.3S: Features: EN 60950 certified, rated for 250VAC UL-60950-1 / CSA C22.2 certified 5.2kVDC Isolation for 1 Minute Optional Continuous Short Circuit Protected Wide Temperature Performance at full 1 Wa...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
| (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified) | ||
| Input Voltage Range |
±10% | |
| Output Voltage Accuracy |
±5% | |
| Line Voltage Regulation |
1.2%/1% of Vin typ. | |
| Load Voltage Regulation | 3.3, 5V output types |
15% max. |
| 10% to 100% full load) | other output types |
10% max. |
| Output Ripple and Noise (20MHz BW) |
200mVp-p max. | |
| Operating Frequency |
20kHz min. / 50kHz typ. / 85kHz max | |
| Efficiency at Full Load |
65% min. / 75% typ. | |
| No Load Power Consumption |
148mW min. / 220mW typ. / 355mW max | |
| Isolation Voltage | (tested for 1 minute) |
5200VDC min. |
| Rated Working Voltage | (long term isolation) |
see Application Notes |
| Isolation Capacitance |
4pF min. / 10pF max. | |
| solation Resistance |
15 GΩ min. | |
| Short Circuit Protection |
1 Second | |
| P-Suffix |
Continuous | |
| Operating Temperature Range (free air convection) |
-40°C to +85°C (see Graph) | |
| Storage Temperature Range |
-55°C to +125°C | |
| Relative Humidity |
95% RH | |
| Package Weight |
4.3g | |
| MTBF(+25°C) Detailed Information see | using MIL-HDBK 217F |
2974 x 103 hours |
| (+85°C) Application Notes chapter "MTBF" | using MIL-HDBK 217F |
728 x 103 hours |
The RxxPxxS_D Series of DC/DC Converters are fully certified to EN 60950/ UL-60950-1 and CSA C22.2. This makes them ideal for all telecom and safety applications where approved isolation is required.