Parameter |
Symbol |
Rating |
Unit | ||
|
S202SE1/S202SE2 |
S216SE1/S216SE2 | ||||
| Input | Forward current |
IF |
50 |
mA | |
| Reverse voltage |
VR |
6 |
V | ||
| Output | RMS ON-state current |
IT |
*48 |
*516 |
Arms |
| *1Peak one cycle surge current |
Isurge |
80 |
160 |
A | |
| Repetitive peak OFF-state voltage |
VDRM |
600 |
V | ||
| Non-repetitive peak OFF-state voltage |
VDSM |
600 |
V | ||
| Critical rate of rise of ON-state current |
dIT/dt |
50 |
A/s | ||
| Operating frequency |
f |
45 to 65 |
Hz | ||
|
*2 Isolation voltage |
Viso |
3,000 |
Vrms | ||
|
Operating temperature |
Topr |
- 25 to + 100 |
°C | ||
|
Storage temperature |
Tstg |
- 30 to + 125 |
°C | ||
|
*3 Soldering temperature |
Tsol |
260 |
°C | ||
*1 60Hz sine wave, Tj = 25°C start withstand voltage tester with zero-cross circuit. (Input and output shall be shorted respectively) .(Note) When the isolation voltage is necessary at using external heat sink, please use the insulation sheet.(Need of the insulation sheet when mounting external heat sink )
1. Comforms to European Safety Standard (EN60950)
*2 AC 60Hz for 1 minute, 40 to 60% RH, Apply voltages between input and output by the dielectric
*3 For 10 seconds *4 TC<=80°C *5 TC<=60°C
1. Comforms to European Safety Standard (EN60950)
(Need of the insulation sheet when mounting external heat sink )
Internal insulation distance : 0.4mm or more
Creepage distance : 5mm or more
Space distance : 4mm or more
2. RMS ON-state current
S202SE1 / S202SE2 : 8Arms at Tc <= 80°C
( with heat sink)
S216SE1 / S216SE2 : 16Arms at Tc <= 60°C
( with heat sink)
3.Isolation voltage. .between input and output (V : 3 000V)
4. Approved by TUV, No. R9051479
5. Recognized by UL, No. E94758
(S202SE1/ S202SE2)
Approved by CSA, No. LR63705
(S202SE1, S202SE2 )