DescriptionFeatures of the SB05W05P are:(1)low forward voltage(VFmax=0.55V);(2)fast reverse recovery time(trr max=10ns);(3)low switching noise;(4)low leakage current and high reliability due to highly reliable planar structure. The absolute maximum ratings of the SB05W05P can be summarized as:(1)...
SB05W05P: DescriptionFeatures of the SB05W05P are:(1)low forward voltage(VFmax=0.55V);(2)fast reverse recovery time(trr max=10ns);(3)low switching noise;(4)low leakage current and high reliability due to high...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features of the SB05W05P are:(1)low forward voltage(VFmax=0.55V);(2)fast reverse recovery time(trr max=10ns);(3)low switching noise;(4)low leakage current and high reliability due to highly reliable planar structure.
The absolute maximum ratings of the SB05W05P can be summarized as:(1):the parameter is repetitive peak reverse voltage,the symbol is VRRM,the rating is 50,the unit is V;(2):the parameter is nonrepetitive peak reverse,the symbol is VRSM,the rating is 55,the unit is V;(3):the parameter is average rectified current,the symbol is IO,the rating is 500,the unit is mA;(4):the parameter is surge forward current,the symbol is IFSM,the rating is 5,the unit is A;(5):the parameter is junction temperature,the symbol is Tj,the rating is -55 to +125,the unit is ;(6):the parameter is storage temperature,the symbol is Tstg,the rating is -55 to +125,the unit is .
The electrical characteristics of the SB05W05P can be summarized as:(1):the parameter is forward voltage,the symbol is VF,the condition is IF=500mA,the max is 0.55,the unit is V;(2):the parameter is reverse current,the symbol is IR,the condition is VR=25V,the max is 50,the unit is A;(3):the parameter is capacilance,the symbol is C,the condition is VR=10V,f=1MHz,the typ is 25,the unit is pF;(4):the parameter is reverse voltage,the symbol is VR,the condition is IR=200A,the min is 50,the unit is V;(5):the parameter is reverse recovery time,the symbol is trr,the condition is IF=IR=100mA,the typ is 10,the unit is ns;(6):the parameter is thermal resistance,the symbol is Rthj-a(1),the typ is 300,the unit is /W;(7):the parameter is thermal resistance,the symbol is Rthj-a(2),the typ is 110,the unit is /W.