Features: 1. Plastic package has Underwriters Laboratory Flammability Classification 94V-0 utilizing Flame retardant epoxy molding compound2. 1.0 ampere operation at TL=90 with no thermal runaway3. For use in low voltage, high frequency inverters,free wheeling, and polarity protection applications...
SB120S: Features: 1. Plastic package has Underwriters Laboratory Flammability Classification 94V-0 utilizing Flame retardant epoxy molding compound2. 1.0 ampere operation at TL=90 with no thermal runaway3. ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
| Symbols | SB 120S |
SB 130S |
SB 140S |
SB 150S |
SB 160S |
SB 180S |
SB 1B0S |
Units | |
| Maximum repetitive peak reverse voltage | VRRM | 20 | 30 | 40 | 50 | 60 | 80 | 100 | Volts |
| Maximum RMS voltage | VRMS | 14 | 21 | 28 | 35 | 42 | 56 | 70 | Volts |
| Maximum DC blocking voltage | VDC | 20 | 30 | 40 | 50 | 60 | 80 | 100 | Volts |
| Maximum average forward rectified current 0.375" (9.5mm) lead length at TL=90 |
I(AV) | 1.0 | Amp | ||||||
| Peak forward surge current, IFM (surge): 8.3mS single half sine-wave superimposed on rated load (MIL-STD-750D 4066 method) |
IFSM | 30.0 | Amps | ||||||
| Maximum forward voltage at 1.0A | VF | 0.55 | 0.70 | 0.85 | Volts | ||||
| Maximum full load reverse current, full cycle average at TA=75 |
IR(AV) | 30.0 | mA | ||||||
| Maximum DC reverse current TA=25 at rated DC blocking voltage TA=100 |
IR | 1.0 10.0 |
mA | ||||||
| Typical junction capacitance (Note 1) | CJ | 110.0 | F | ||||||
| Typical thermal resistance (Note 2) | RJA | 80.0 | /W | ||||||
| Operating and storage temperature range | TJ, TSTG | -50 to +125 | |||||||