Features: • AND-Gated (Enable/Disable) Serial Inputs• Fully Buffered Clock and Serial Inputs• Direct Clear• Package Options Include Plastic Small-Outline (D) Packages and Standard Plastic (N) 300-mil DIPsPinoutSpecificationsSupply voltage, VCC . . . . . . . . . . . .. . . ....
SN74ALS164A: Features: • AND-Gated (Enable/Disable) Serial Inputs• Fully Buffered Clock and Serial Inputs• Direct Clear• Package Options Include Plastic Small-Outline (D) Packages and Sta...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

Supply voltage, VCC . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
† Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
This SN74ALS164A 8-bit parallel-out serial shift register features AND-gated serial (A and B) inputs and an asynchronous clear (CLR) input. The gated serial inputs permit control over incoming data because a low at either input inhibits entry of the new data and resets the first flip-flop to the low level at the next clock pulse. A high-level input enables the other input, which determines the state of the first flip-flop. Data at the serial inputs can be changed while the clock is high or low, provided that the minimum setup-time requirements are met. Clocking occurs on the low-to-high-level transition of the clock (CLK) input. All inputs are diode clamped to minimize transmission-line effects.
The SN74ALS164A is characterized for operation from 0°C to 70°C.