PinoutDescriptionThe SN74LVC245ADB is designed for asynchronous communication between data buses. The device transmits data from the A bus to the B bus or from the B bus to the A bus, depending on the logic level at the direction-control (DIR) input. The output-enable (OE) input can be used to dis...
SN74LVC245ADB: PinoutDescriptionThe SN74LVC245ADB is designed for asynchronous communication between data buses. The device transmits data from the A bus to the B bus or from the B bus to the A bus, depending on t...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

The SN74LVC245ADB is designed for asynchronous communication between data buses. The device transmits data from the A bus to the B bus or from the B bus to the A bus, depending on the logic level at the direction-control (DIR) input. The output-enable (OE) input can be used to disable the device so the buses are effectively isolated.
Features of the SN74LVC245ADB are:(1)EPIC(enhanced-performance implanted CMOS) submicron process;(2)typical VOLP (output ground bounce) < 0.8V at Vcc=3.3V,TA=25;(3)typical VOHV (output VOH undershoot) > 2V at Vcc=3.3V,TA=25;(4)supports mixed-mode signal operation on all ports(5-V input/output voltage with 3.3-V VCC);(5)power off disables outputs,permitting live insertion;(6)ESD protection exceeds 2000 V per;(7)latch-up performance exceeds 250 mA per JESD 17;(8)package options include plastic.
The absolute maximum ratings of the SN74LVC245ADB can be summarized as:(1):the parameter is supply voltage range,the symbol is VCC,the rating is -0.5 to 6.5,the unit is V;(2):the parameter is input voltage range,the symbol is VI,the rating is -0.5 to 6.5,the unit is V;(3):the parameter is voltage range applied to any output in the high-impedance or power-off state,the symbol is VO,the rating is -0.5 to 6.5,the unit is V;(4):the parameter is voltage range applied to any output in the high or low state,the symbol is VO,the rating is -0.5 to Vcc+0.5,the unit is V;(5):the parameter is input clamp current,the symbol is IIK,the rating is -50,the unit is mA;(6):the parameter is output clamp current,the symbol is IOK,the rating is -50,the unit is mA;(7):the parameter is continuous output current,the symbol is IO,the rating is ±50,the unit is mA;(8):the parameter is continuous current through Vcc or GND,the symbol is IO,the rating is ±100,the unit is mA;(9):the parameter is package thermal impedance DB package,the symbol is JA,the rating is 115,the unit is /W;(10):the parameter is storage temperature range,the symbol is Tstg,the rating is -65 to 150,the unit is .