Features: Supports a 9-Pin GeoPort Host Interface Standard for the Intelligent Network PortDesigned to Operate up to 4-Mbit/s Full Duplex ±5 V Supply Operation Provides 6 kV ESD Protection Has Driver Short-Circuit Protection Includes Failsafe Mechanism for Open Inputs Is Backward Compatib...
SN75LBC771: Features: Supports a 9-Pin GeoPort Host Interface Standard for the Intelligent Network PortDesigned to Operate up to 4-Mbit/s Full Duplex ±5 V Supply Operation Provides 6 kV ESD Protection ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

Positive supply voltage range, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 to 7 V
Negative supply voltage range, VEE (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . 7 to 0.5 V
Receiver input voltage range (RA, RB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 V to 15 V
Receiver differential input voltage range, VID . . . . . . . . . . . . . . . . . . . . . . . . . . 12V to 12 V
Receiver output voltage range (RY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 5.5 V
Driver output voltage range (Power Off) (,DY1, DY2, DZ2) . . . . . . . . . . . . . . . . 15 V to 15 V
Driver output voltage range (Power On) (,DY1, DY2, DZ2) . . . . . . . . . . . . . . . . 11 V to 11 V
Driver input voltage range (DA, SHDN, ,DEN) . . . . . . . . . . . . . . . . . . . . 0.5 V to VCC +0.4 V
Electrostatic Discharge (see Note 2)
(All pins) Class 3, A . . . . . . . . . . . . . . . . . . . . . . . . . . 6 kV
(All pins) Class 3, B . . . . . . . . . . . . . . . . . . . . . . . . . . 500 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . .See Dissipation Rating Table
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . 260°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to network ground terminal unless otherwise noted.
2. This rating is per MIL-STD-883C, Method 3015.7.