Features: ` TYPICAL RDS(on) = 3.25 ` ± 30V GATE TO SOURCE VOLTAGE RATING` 100% AVALANCHE TESTED` REPETITIVE AVALANCHE DATA AT 100` LOW INTRINSIC CAPACITANCES` GATE CHARGE MINIMIZED` REDUCED THRESHOLD VOLTAGE SPREAD` THROUGH-HOLE IPAK (TO-251) POWER PACKAGE IN TUBE (SUFFIX -1 )` SURFACE-MOUNTING D...
STD2NA50: Features: ` TYPICAL RDS(on) = 3.25 ` ± 30V GATE TO SOURCE VOLTAGE RATING` 100% AVALANCHE TESTED` REPETITIVE AVALANCHE DATA AT 100` LOW INTRINSIC CAPACITANCES` GATE CHARGE MINIMIZED` REDUCED THRESHOL...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
|
Symbol |
Parameter |
Value |
Unit |
|
VDS |
Drain-source Voltage (VGS = 0) |
500 |
V |
|
VDGR |
Drain-gate Voltage (RGS = 20 k) |
500 |
V |
|
VGS |
Gate- source Voltage |
± 30 |
V |
|
ID |
Drain Current (continuos) at TC = 25 |
2.2 |
A |
|
ID |
Drain Current (continuos) at TC = 100 |
1.4 |
A |
|
IDM (`) |
Drain Current (pulsed) |
8.8 |
A |
|
Ptot |
Total Dissipation at TC = 25 |
45 |
W |
| Derating Factor |
0.36 |
W/ | |
|
Tstg |
Storage Temperature |
-65 to 150 |
|
|
Tj |
Max.Operating Junction Temperature |
150 |