Purchase T4 Series, In-stock T4 Series From SeekIC.


Part Number: T4 Series
Description: Based on ST's Snubberless / Logic level technology providing high commutation performances, the T4 ser...


Description: Based on ST's Snubberless / Logic level technology providing high commutation performances, the T4 ser...
Based on ST's Snubberless / Logic level technology providing high commutation performances, the T4 series is suitable for use on AC inductive loads. They are recommended for applications using universal motors, electrovalves.... such as kitchen aid equipments, power tools, dishwashers,... Available in a fully insulated package, the T4...-...W version complies with UL standards (ref. E81734).
|
Symbol |
Parameter |
Value |
Unit | ||
|
IT(RMS) |
RMS on-state current (360° conduction angle) |
DPAK / IPAK TO-220AB |
Tc =110°C |
4 |
A |
|
ISOWATT 220AB |
Tc = 105°C | ||||
|
ITSM |
Non repetitive surge peak on-state current (Tj initial = 25°C) |
F = 50 Hz |
t = 20 ms |
30 |
A |
|
F = 60 Hz |
t = 16.7 ms |
31 | |||
|
I2t |
I2t Value for fusing |
tp = 10 ms |
5.1 |
A2s | |
|
dI/dt |
Critical rate of rise of on-state current IG = 2 x IGT , tr £ 100 ns |
F = 120 Hz |
Tj = 125°C |
50 |
A/s |
| IGM | Peak gate current |
tp = 20 s |
Tj = 125°C |
4 |
A |
| PG(AV) | Average gate power dissipation |
Tj = 125°C |
1 |
W | |
|
Tstg |
Storage temperature range |
- 40, + 150 |
°C | ||
|
Tj |
Operating junction temperature range |
- 40, + 125 | |||