Features: SpecificationsDescription The VZS-3530J1 is designed as a 4250 watt TWT compact pulsed amplifier.VZS-3530J1 has four features.The irst one is about its compact which has eight rack-units tall (14.0 in/356 mm).The second one is about its vrsatile.For example it has the function of wide ba...
VZS-3530J1: Features: SpecificationsDescription The VZS-3530J1 is designed as a 4250 watt TWT compact pulsed amplifier.VZS-3530J1 has four features.The irst one is about its compact which has eight rack-units t...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The VZS-3530J1 is designed as a 4250 watt TWT compact pulsed amplifier.
VZS-3530J1 has four features.The irst one is about its compact which has eight rack-units tall (14.0 in/356 mm).The second one is about its vrsatile.For example it has the function of wide band, automatic fault recycle, user-friendly microprocessor-controlled logic with integrated computer interface, digital metering, and quiet operation suitable for laboratory environments.Also an integral solid state preamplifier and IEEE interface are included as standard features.The third one is that it has a support of global applications which has a 230 VAC operation.It is designed to meet the international safety standard EN61010 and electromagnetic compatibility 2004/108/EC.The last one is that it will be easy to maintain.The CPI company has a worldwide 24-hour
customer support network that includes sixteen regional factory service centers.So its modular design and built-in fault diagnostic capability will make the customers feel good.
Some specifications of the VZS-3530J1 has been concluded into several points.The first one is about its frequency which should be 2.0 to 4.0 GHz.The second one is about its ambient temperature which should be -10° to +40°C when operating and -40° to +70°C when non-operating.The third one is about its relative humidity which should be 95% non-condensing.The fourth one is about its altitude which should be 10,000 ft. with standard adiabatic
derating of 2°C/1000 ft. when operating and 40,000 ft. when non-operating.The fifth one is about its shock and vibration which should be as normally encountered in a protected laboratory environment.The sixth one is about its primary power which should be 220 - 240 VAC with ±10% wave,single phase 47- 63 Hz.The last one is its weight which should be 150 lbs (55 kg) max.
Two options have been given which should be noted.The first one is remote control panel.The second one is input isolator(-1 dB gain).That all the options.