Features: SpecificationsDescription The VZS/C-6963J2 Series is designed as a compact HPA,with250W or 340W traveling wave tube. VZS/C-6963J2 has four features.The first one isabout its compactwhich means it has five rack units tall (8.75 in, 222 mm).The second one is about its versatile.For example...
VZS/C-6963J2: Features: SpecificationsDescription The VZS/C-6963J2 Series is designed as a compact HPA,with250W or 340W traveling wave tube. VZS/C-6963J2 has four features.The first one isabout its compactwhich m...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: SpecificationsDescription The VZS/C-2780C2 is designed as a 500 watt TWT high power ampl...
Features: SpecificationsDescription The VZS/X-2776L1 is designed as compact medium power amplifier...
The VZS/C-6963J2 Series is designed as a compact HPA,with 250W or 340W traveling wave tube.
VZS/C-6963J2 has four features.The first one is about its compact which means it has five rack units tall (8.75 in, 222 mm).The second one is about its versatile.For example it has the function of automatic fault recycle, userfriendly microprocessor-controlled logic with integrated computer interface,Ultra-wideband, digital metering,electronic variable attenuation, soft-fail when subjected to extreme load SWR conditions,quiet operation for laboratory environment.The third one is that it is designed tobe global applications.It has 230 VAC operation,and also meets international safety standard EN61010 and electromagnetic compatibility 89/336/EEC.The last one is that it has a worldwide support.The CPI company has the worldwide 24-hour customer support network that includes fifteen regional factory service centers.So customerswould be easy to get the modular design and built-in fault diagnostic capability.
Some important specifications of VZS/C-6963J2 have been given into several points.The first one is that its frequency would be 2.0 to 8.0 GHz.The second one is about bandwidth would be 6.0 GHz.The third one is ambient aemperature which should be -10° to +40°C when operating.The fourth one is about its altitude up to 10,000 ft (3000 m) with standard adiabatic derating of 2°/1000 ft.The fifth one is about shock and vibration which is designed to meet conditions normally encountered in the laboratory.The sixth one is about its primary power which should be within 220-240 VAC and ±10% wave, single phase,47-63 Hz.The seventh one is about its relative humidity which should be 95% non-condensing.The eighth one is about its acoustic noise which would be 65 dBA @ 3 ft. from amplifier.The last one is about its safety standdard which meets the EN61010 standard.
Three options should be noted.The first one is input isolator(-1 dB gain).The secomd one is remote control panel.The third one that 115 VAC external step-up transformer.That all the options.