Features: ·LED direct drive by time-sharing (duplex)·Wide operating voltage range·Alarm on a 24-hour basis·Time format: 12-hour AM/PM and 24 hour ·On-chip RC-oscillator for battery backup·50Hz or 60Hz is usable as the reference frequency·Possible to automatically advance hours , minutes ·Sleep ...
IL8560: Features: ·LED direct drive by time-sharing (duplex)·Wide operating voltage range·Alarm on a 24-hour basis·Time format: 12-hour AM/PM and 24 hour ·On-chip RC-oscillator for battery backup·50Hz or 60...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Characteristic |
Symbol |
Value |
Unit |
Maximum Supply Voltage |
VDD |
-15 - + 0.3 |
V |
Input Voltage |
VIN |
-15 - + 0.3 |
V |
Output Voltage |
VOUT |
-15 -+ 0.3 |
V |
Input Clamp Current (50/60Hz Input) |
IIN |
-0.4 - + 0.4 |
mA |
Allowable Power Dissipation (TA = 70 ) |
Pdmax |
0.7 |
W |
Operating Temperature |
TA |
- 30 - + 70 |
|
Storage Temperature |
Tstg |
- 55 - + 125 |
|
50Hz/60Hz Input: The on-chip Schmitt trigger circuit of the IL8560 allows a simple RC filter at the input to remove possible line oltage transients. An internal pull-up resister is provided.
CR Input of the IL8560: Then AC power-down occurs, the time counter enters the "hold" mode and the on-chip clock oscillator starts operating immediately. If there is no input at "50/60 Hz input" during 3-clock period, this oscillator controls the time cou nter advance instead of "50/60Hz input". The values of CR determine the frequency of the on-chip clock oscillator. All s egment outputs are off during backup oscillator operation. NOTE: If the backup OSC is used at the power-down mode, "50/60Hz input" must be open or at Vss level.
50/60 select input of the IL8560: Connecting "50/60Hz select" to Vss enables 50Hz operation. For 60Hz operation, "50/60Hz select" is left unconnected: Pull-down to VDD is provided by the internal pulldown resister.
Display mode select input (alarm display/sleep display); The internal pull-down resistor allows the use of 2 SPST (single-pole single- throw) switches to select 4 display modes listed in Table 1.