Purchase 344601, In-stock 344601 From SeekIC.

Electrical: 348 Series: Rated at 15 amps for any voltage up to 250 volts.
344 Series: Rated at 15 amps at lamp voltage shown below.
Dielectric Strength: 1500 volts minimum.
When designing indicating type fuseholders into a circuit, consideration should be given to the resistance of fractional amperage fuses and the parallel resistance of the indicator lamp and its resistor.
Mounting: Panel thickness range: .031" through .125".
Molded Parts: Black phenolic body (UL 94V0). Thermoplastic bezel, cap and lens (UL94V2).See tables below for colors.
Terminals: Brass.Tin-plated.
Ambient Temperature:
Non-indicating: 40°C to +85°C.
Indicating: 40°C to +60°C.
Fuse Installation: Insert a fuse into the cap and push the assembly into the body until it latches.Press in and down to unlatch for removal.
344601