Features: · 300W DC Transformer for DPA Front End· Industry Standard ¼ Brick Footprint· High Efficiency· Positive and Negative Enable Options· Regulation to Zero Load· Meets Basic Insulation· Input OVP and UVLO· Low profile / open-frameSpecifications Parameter Device Symbol ...
ALQ25B50N-6: Features: · 300W DC Transformer for DPA Front End· Industry Standard ¼ Brick Footprint· High Efficiency· Positive and Negative Enable Options· Regulation to Zero Load· Meets Basic Insulation·...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter |
Device |
Symbol |
Min |
Max |
Unit |
Input Voltage1 Continuous Transient (100ms) |
All All |
VIN VIN,trans |
42 - |
56 60 |
V V |
Isolation Voltage Input to Output |
All |
- |
2000 |
V | |
Operating Ambient Temperature |
All |
TA |
-40 |
85 |
ºC |
Storage Temperature |
All |
TSTG |
-55 |
125 |
ºC |
Operating Humidity |
All |
- |
- |
85 |
% |
Maximum Enable Voltage |
All |
5.5 |
V | ||
Max Output Power2 |
All |
PO |
- |
300 |
W |