Specifications Symbol Characteristic Conditions Tj[°C] Value Unit BLOCKING V RRM Repetitive peak reverse voltage 125 6000 V V RSM Non-repetitive peak reverse voltage 125 6100 V I RRM Repetitive peak reverse current V=VRRM 125 MA V DC LINK Permanent DC ...
ARF794HT: Specifications Symbol Characteristic Conditions Tj[°C] Value Unit BLOCKING V RRM Repetitive peak reverse voltage 125 6000 V V RSM Non-repetitive peak reverse voltage 1...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
| Symbol | Characteristic | Conditions | Tj [°C] |
Value | Unit |
| BLOCKING | |||||
| V RRM | Repetitive peak reverse voltage |
125 | 6000 | V | |
| V RSM | Non-repetitive peak reverse voltage | 125 | 6100 | V | |
| I RRM | Repetitive peak reverse current | V=VRRM | 125 | MA | |
| V DC LINK | Permanent DC voltage | 125 | 3200 | v | |
CONDUCTING | |||||
| I F (AV) | Mean forward current | 180° sin ,50 Hz, Th=55°C, double side cooled | 1060 | A | |
| I F (AV) | Mean forward current | 180° sin ,50 Hz, Tc=55°C, double side cooled | 1110 | A | |
| I FSM | Surge forward current | Sine wave, 10 ms without reverse voltage up to 50% VRSM |
125 | 20 | KA |
| I² t | I² t | 2000 x 1E3 | A²s | ||
| V FM | Forward voltage | Forward current =1570 A | 25 | 5.6 | V |
| V F(TO) | Threshold voltage | 125 | 2.10 | V | |
| r F | Forward slope resistance | 125 | 1.40 | mohm | |
| SWITCHING | |||||
| Q rr | Reverse recovery charge | I F = 1000 A di/dt= 250 A/µs VR = 100 V |
125 | µC | |
| I rr | Peak reverse recovery current | 125 | A | ||
| t rr | Reverse recovery time | I F = 1000 A di/dt= 500 A/µs VR = V |
125 | µs | |
| Q rr | Reverse recovery charge | 4000 | µC | ||
| I rr | Peak reverse recovery current | 1600 | A | ||
| s | Softness (s-factor), min | ||||
| E OFF | Turn off energy dissipation | v | |||
| V FR | Peak forward recovery | di/dt = 500 A/µs | 125 | v | |
| MOUNTING | |||||
| R th(j-h) | Thermal impedance, DC | Junction to heatsink, double side cooled | 11 | °C/kW | |
| R th(c-h) | Thermal impedance | Case to heatsink, double side cooled | 2 | °C/kW | |
| T j | Operating junction temperature | -30 / 125 | °C | ||
| F | Mounting force | 46.0/54.0 | kN | ||
| Mass | 1700 | g | |||