C4900

Features: Compact and Lightweight High stability Low Power Consumption Fast Response Wide Variable Output Range Ample Protective and Failsafe FunctionsSpecifications Parameter C4900 C4900-01 C4900-50 C4900-51 Unit Input Voltage Range +15 ± 1 +12 ± 0.5 +15 ± 1 ...

product image

C4900 Picture
SeekIC No. : 004309534 Detail

C4900: Features: Compact and Lightweight High stability Low Power Consumption Fast Response Wide Variable Output Range Ample Protective and Failsafe FunctionsSpecifications Parameter C4900 C4...

floor Price/Ceiling Price

Part Number:
C4900
Supply Ability:
5000

Price Break

  • Qty
  • 1~5000
  • Unit Price
  • Negotiable
  • Processing time
  • 15 Days
Total Cost: $ 0.00

SeekIC Buyer Protection PLUS - newly updated for 2013!

  • Escrow Protection.
  • Guaranteed refunds.
  • Secure payments.
  • Learn more >>

Month Sales

268 Transactions

Rating

evaluate  (4.8 stars)

Upload time: 2024/4/26

Payment Methods

All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

Notice: When you place an order, your payment is made to SeekIC and not to your seller. SeekIC only pays the seller after confirming you have received your order. We will also never share your payment details with your seller.
Product Details

Description



Features:

Compact and Lightweight
High stability
Low Power Consumption
Fast Response
Wide Variable Output Range
Ample Protective and Failsafe Functions



Specifications

Parameter
C4900
C4900-01
C4900-50
C4900-51
Unit
Input Voltage Range
+15 ± 1
+12 ± 0.5
+15 ± 1
+12 ± 0.5
V
Input Current with no load
14
15
14
15
mA (Typ.)
with full load
90
95
90
95
Variable Output Range
0 to 1250
0 to +1250

V

Specification Guaranteed
Output Voltage Range
200 to 1250
+200 to +1250
V
Output Current
0.6
0.5
0.6
0.5
mA (Max.)
Line Regulation against ±1 V or 0.5 V Change (b)
± 0.01
% (Typ.)
Load Regulation against
0 % to 100 % Load Change (a)
± 0.01
% (Typ.)
Ripple / Noise (p-p)(b)
0.007
% (Typ.)
Output Voltage Controlling Modes
By external controlling voltage (+0.8 to +5 V) or external potentiometer (10 k )
-
Controlling Voltage Input Impedance
80
k (Typ.)
Reference Voltage Output
+5.13 (with 50 kΩ external potetiometer)

V (Typ.)

Output Voltage Setting(Absolute value)
±(Controlling voltage X 250) ± 0.5%
V (Typ.)
Output Voltage Rise Time (0 % 99 %) (b)
50
ms (Typ.)
Temperature Coefficient (b)
±0.01
%/ (Typ.)
Operating Temperature Range (b)
0 to +50
oC
Storage Temperature Range
-20 to +70
oC
Dimensions (W X H X D)
46X 24 X12
mm
Weight
31
g
Protective Functions
Units protected against reversed power input, reversed/excessive controllingvoltage input, continuous overloading/short circuit in output
-



Description

The C4900 series are compact PCboard mountable high voltage power supplies, especially designed for photomultiplier tubes. The design offers better performance and improved failsafe protection.

The C4900 and01 output negative polarity and the C490050 and 51 output positive polarity high voltages.