Purchase CY2XP306, In-stock CY2XP306 From SeekIC.


|
Parameter |
Description | Condition |
Min. |
Max. |
Unit |
|
VDD |
Supply Voltage | Non-functional |
0.3 |
4.6 |
V |
|
VDD |
Operating Voltage | Functional |
3.135 |
3.465 |
V |
|
VTT |
Output Termination Voltage | Relative to VDD[1] |
VDD 2 |
V | |
|
VIN |
Input Voltage | Relative to VDD[1] |
0.3 |
VDD + 0.3 |
V |
|
VOUT |
Output Voltage | Relative to VDD[1] |
0.3 |
VDD + 0.3 |
V |
|
LUI |
Latch Up Immunity | Functional |
100 |
mA | |
|
TS |
Temperature, Storage | Non-functional |
65 |
+150 |
°C |
|
TA |
Temperature, Operating Ambient | Functional |
40 |
+85 |
°C |
|
TJ |
Temperature, Junction | Non-functional |
150 |
°C | |
|
ØJc |
Dissipation, Junction to Case | Functional |
11.48 |
°C/W | |
|
ØJa |
Dissipation, Junction to Ambient | Functional |
85.8 |
°C/W | |
|
ESDh |
ESD Protection (Human Body Model) |
2000 |
V | ||
|
MSL |
Moisture Sensitivity Level |
3 |
N.A. | ||
CY2XP306