Purchase KGL4115HW-R, In-stock KGL4115HW-R From SeekIC.


| Parameter | Symbol | Min | Max | Unit | Note |
| Supply Voltage | VS | -6.5 | 0.3 | V | |
| X-Point Control Voltage | VB1 | VS-4.5 (Min. -6.5) |
VS+2.4 (Max. 0.3) |
V | |
| Output Amplitude Control Voltage | VC1 | -6.5 | VS+1.2 (Max. 0.3) |
V | |
| Output Bias Control Voltage | VC2 | -6.5 | VS+2.4 (Max. 0.3) |
V | |
| Operating Temperature at Package Base |
Ts | -10 | 100 | ||
| Storage Temperature | Tst | -40 | 125 |
1. For stable operation;
1-1. To prevent a dependence of "X-Point" on the supply voltage VS,
(1) Use an external voltage source of 3.8V for "VB2", or
(2) Control the voltage of "VB1", so that the voltage difference "VB1VB2" is constant.
1-2. To prevent a dependence of "Output amplitude" on the supply voltage VS, Control the voltage of "VC1", so that the voltage difference "VC1VS" is constant.
1-3. To prevent a dependence of "Output bias control voltage" on supply voltage VS, Control the voltage of "VC2", so that the voltage difference "VC2VS" is constant.
2. Power-up/shut-down sequence;
For power-up, supply control voltages (VB1, (VB2), VC1, VC2) at first, then Vs. For shut-down, Vs at first, then control voltages.
Customer does not need to care about the sequence for the control voltages (VB1,(VB2),VC1,VC2).
3. Under "no signal input" condition, the operation may not be stable.
KGL2115
PDF/DataSheet Download