MAX1946 Maximum Ratings
IN, ON, OUT, SEL to GND..........................................-0.3V to +6V
FAULT to GND...............................................-0.3V to (VIN + 0.3V)
IN to OUT..................................................................-0.3V to +6V
OUT Continuous Switch Current (internally limited)..............1.3A
FAULT DC Current................................................................10mA
Continuous Power Dissipation (TA = +70°C)
Exposed Pad Must be Soldered to PC Board
8-Pin QFN (derate 24.4mW/°C above +70°C) ...........1951mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature.......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
MAX1946 Features
Single USB Switch in 3mm x 3mm Package
Autoreset Feature Saves System Power
Guaranteed 500mA Load Current
Built-In 20ms Fault-Blanking Circuitry
Active-High or Active-Low Control Logic
Fully Compliant to USB Specifications
2.7V to 5.5V Input Voltage Range
Fault-Indicator Output
Thermal-Overload Protection
UL Certification Pending
MAX1946 Typical Application
USB Ports and USB Hubs
Notebook and Desktop Computers
PDAs and Palmtop Computers
Digital Cameras
Docking Stations
MAX1946 Connection Diagram