NT1+/UR2

Features: · COMBINED AC+DC CONVERTER FOR ISDN NT1+ APPLICATION· Uo INTERFACE (DC) AND MAIN (AC) INPUTS TO ENABLE NPM (Normal Power· Mode) AND RPM (Restricted Power Mode) CONDITIONS· INPUT FILTER TO MEET EMC REQUIREMENTS 5 INSULATED MAIN OUTPUTS· PEAK INPUT OVERVOLTAGE WITHSTANDING INPUT FUSE ON AC...

product image

NT1+/UR2 Picture
SeekIC No. : 004435765 Detail

NT1+/UR2: Features: · COMBINED AC+DC CONVERTER FOR ISDN NT1+ APPLICATION· Uo INTERFACE (DC) AND MAIN (AC) INPUTS TO ENABLE NPM (Normal Power· Mode) AND RPM (Restricted Power Mode) CONDITIONS· INPUT FILTER TO ...

floor Price/Ceiling Price

Part Number:
NT1+/UR2
Supply Ability:
5000

Price Break

  • Qty
  • 1~5000
  • Unit Price
  • Negotiable
  • Processing time
  • 15 Days
Total Cost: $ 0.00

SeekIC Buyer Protection PLUS - newly updated for 2013!

  • Escrow Protection.
  • Guaranteed refunds.
  • Secure payments.
  • Learn more >>

Month Sales

268 Transactions

Rating

evaluate  (4.8 stars)

Upload time: 2024/4/26

Payment Methods

All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

Notice: When you place an order, your payment is made to SeekIC and not to your seller. SeekIC only pays the seller after confirming you have received your order. We will also never share your payment details with your seller.
Product Details

Description



Features:

·  COMBINED AC+DC CONVERTER FOR ISDN
   NT1+ APPLICATION
·  Uo INTERFACE (DC) AND MAIN (AC) INPUTS
   TO ENABLE NPM (Normal Power
·  Mode) AND RPM (Restricted Power Mode)
   CONDITIONS
 ·  INPUT FILTER TO MEET EMC REQUIREMENTS
   5 INSULATED MAIN OUTPUTS
·  PEAK INPUT OVERVOLTAGE WITHSTANDING
   INPUT FUSE ON AC MAIN INPUT
   INPUTS TO OUTPUTS INSULATION
·  AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE
   FOR NPM/RPM MODE INDICATION
   (EM SIGNAL & GREEN LED). 3mA OUTPUT
   SOURCE CURRENT
·  AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE
   FOR U-INTERFACE DETECTION (RED
   LED). 3mA OUTPUT SOURCE CURRENT
·  AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE
   FOR AUTO SETTING TO ISDN OR
·  ANALOG PHONE CONNECTION TO U-INTERFACE
   (RELAY). 3mA OUTPUT SOURCE
   CURRENT
·  INTERNAL RELAY FUNCTION FOR Vo1 POLARITY
   REVERSE
·  ANALOG OUTPUTS EMERGENCY CONDITION
   PROGRAMMABLE VIA EXTERNAL
·  COMMAND, TTL COMPATIBLE, 1mA SINK
    CURRENT
·  U-INTERFACE ACCORDING TO ETR 080
   WITH EXTERNAL CAPACITOR </= 2.2 uF
   S-INTERFACE ACCORDING TO ETS 300
   012
·  SAFETY COMPLIANCE ACCORDING TO
   EN60950
·  MECHANICAL DIMENSIONS (LxWxH):
   96x58x26.6



Description

The NT1+/UR2 Power Management Module is a comprehensive solution for ISDN-NT1 "Plus" (Network Termination Basic Access type Plus) equipment, combining both AC-DC and DC-DC functions.

The NT1+/UR2 Power Management Module (NT1+ PMM) provide the NT1+ equipment with all necessary supply voltages as well as control signals to operate in the different operating modes, typically the Normal Power Mode (NPM) and the Restricted Power Mode (RPM).

Connected to the main, Input 1 is the AC input power to the NT1+/UR2, source of the whole necessary power in normal operating mode, namely in NPM. Input 2 is the DC power source when in RPM, therefore to connect to the U-Interface. When the main is available (230 Vac in this version) NT1+/UR2 operate in Normal Power Mode, therefore it supply +40V (output 1) to the S-Interface being the output power 4.5 W. Output 2 delivers 5V (up to 720mW) for the logics and output 3 delivers -21V (up to 900 mW). Out voltage 4 is -50V with 100 mW output power. Last, output 5 delivers -150V and the output power can reach peaks of 700 mW.

When the main is missing, the module NT1+/UR2 remains active but only in Restricted Power Mode (RPM).

The only power source in RPM of NT1+/UR2 is the Input 2, the U-Interface (Vi2). Therefore in RPM the following condition apply to outputs 1 and 2: output 1 reverses the voltage (it becomes -40V) and the maximum power Pout is reduced to 420 mW. P2max is reduced to 450 mW typically, however the output power available at outputs 2,3,4,5 mainly depend on input power available from the "U Interface" Vi2, therefore subject of variation as per local application and regulation.

In RPM of NT1+/UR2 it is also possible to set a different "emergency condition" setting HIGH the auxiliary input 3 (analog emergency input, Vin3). In this case Pout1 is reduced to 25mW, voltage level being -40V.

The following tables give you details of the various parameters in the 3 different operating modes of NT1+/UR2, namely NPM, RPM with Vi3 LOW, RPM with Vi3 HIGH.

NT1+/UR2's Availability of the input AC main is also acknowledged by a specific auxiliary output (out 6, "EM signal"), a TTL-compatible signal set HIGH (to logic level "1") when the main is available and LOW when the AC main is missing.

An auxiliary output (Output RELAY, pin 11) is available from NT1+/UR2 for U-INTERFACE voltage level acknowledge, the threshold level being fixed at 85 V. When U-INTERFACE voltage level is below 85 V, a POTS is connected therefore the auxiliary relay output is LOW. Vice versa, this output goes HIGH when U is higher than 85V (ISDN line card).

The presence of the "U" is detected by an other auxiliary output (out 7)of NT1+/UR2 that is HIGH only when Vin2 >34V.

The NT1+/UR2 provides double insulation (3000 Vrms) between the inputs (1 and 2), and among the input 1 and all the outputs. Basic insulation exists among Out1 and all other outputs. The other outputs (including the 2 auxiliary outputs) and the input 3, share the same common ground. Double insulation (2000 Vrms) is provided among Input 2 (DC "U") and all outputs.

The NT1+/UR2 Power Management Module operate in the range -10 to +70 oC, storage temperatures in the range -40 to +85 oC are allowed.




Customers Who Bought This Item Also Bought

Margin,quality,low-cost products with low minimum orders. Secure your online payments with SeekIC Buyer Protection.
Transformers
Sensors, Transducers
RF and RFID
Cables, Wires - Management
Semiconductor Modules
Potentiometers, Variable Resistors
View more