Features: · Performs bidirectional power and energy measurement· Meets the IEC 521/1036 Specification requirements for Class 1 AC Watt hour meters· Protected against ESD· Total power consumption rating below 25mW· Adaptable to different types of current sensors· Operates over a wide temperature ra...
SA9602H: Features: · Performs bidirectional power and energy measurement· Meets the IEC 521/1036 Specification requirements for Class 1 AC Watt hour meters· Protected against ESD· Total power consumption rat...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
· Performs bidirectional power and energy measurement
· Meets the IEC 521/1036 Specification requirements for Class 1 AC Watt hour meters
· Protected against ESD
· Total power consumption rating below 25mW
· Adaptable to different types of current sensors
· Operates over a wide temperature range
· Precision voltage reference on-chip

| Parameter | Symbol | Min | Max | Unit |
| Supply Voltage | VDD -VSS | -0.3 | 6.0 | V |
| Current on any pin | IPIN | -150 | +150 | mA |
| Storage Temperature | TSTG | -40 | +125 | °C |
| Operating Temperature | TO | -40 | +85 | °C |
* Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only. Functional operation of the device at these or any other condition above those indicated in the operational sections of this specification, is not implied. Exposure to Absolute Maximum Ratings for extended periods may affect device reliability.
The SAMES SA9602H is an enhancement of the SA9102H, as no external capacitors are required for the A/D converters. The SA9602H has a higher output pulse rate than the SA9102H.
The SAMES SA9602H Single Phase bidirectional Power/Energy metering integrated circuit generates a pulse rate output, the frequency of which is proportional to the power consumption. The SA9602H performs the calculation for active power.
The method of calculation SA9602H takes the power factor into account.
Energy consumption of SA9602H can be determined by the power measurement being integrated over time.
This innovative universal single phase power/ energy metering integrated circuit, SA9602H is ideally suited for energy calculations in applications such as residential municipal metering and factory energy metering and control.
The SA9602H integrated circuit is available in both 14 and 20 pin dual-in-line plastic (DIP-14/ DIP-20), as well as 20 pin small outline (SOIC- 20) package types.