Features: ` 1A SUPPLY CURRENT ACHIEVED WHEN IN AUTO-POWERDOWN` 250Kbps MINIMUM GUARANTEED DATA RATE` GUARANTEED 6V/ms SLEW RATE RANGE` GUARANTEED MOUSE DRIVEABILITY` 0.1F EXTERNAL CAPACITORS` MEET EIA/TIA-232 SPECIFICATIONS DOWN TO 3V` AVAILABLE IN SO-28, SSOP-28 AND TSSOP28PinoutSpecifications ...
ST3243: Features: ` 1A SUPPLY CURRENT ACHIEVED WHEN IN AUTO-POWERDOWN` 250Kbps MINIMUM GUARANTEED DATA RATE` GUARANTEED 6V/ms SLEW RATE RANGE` GUARANTEED MOUSE DRIVEABILITY` 0.1F EXTERNAL CAPACITORS` MEET E...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

| Symbol | Parameter |
Value |
Unit |
| VCC | Supply Voltage |
-0.3 to 6 |
V |
| V+ | Doubled Voltage Terminal |
(VCC -0.3) to 7 |
V |
| V- | Inverted Voltage Terminal |
0.3 to -7 |
V |
| V+ +|V-| |
13 |
V | |
| FORCEON, FORCEOFF, TIN |
Input Voltage |
-0.3 to 6 |
V |
| RIN | Receiver Input Voltage Range |
± 25 |
V |
| TOUT | Transmitter Output Voltage Range |
± 13.2 |
V |
| ROUT ROUTB INVALID |
Receiver Output Voltage Range |
-0.3 to (VCC + 0.3) |
V |
| tSHORT | Short Circuit Durtion on TOUT (one at a time) |
Continuous |
|
| Tstg | Storage Temperature Range |
-65 to 150 |
The ST3243 device consists of 3 drivers, 5 receivers and a dual charge-pump circuit. The device meets the requirements of EIA/TIA and V.28/V.24 comunication standards providing high data rate capability.
The ST3243 receiver R2 is always active to implement a wake-up feature for serial port.
The ST3243 has a proprietary low-dropout transmitter output stage enabling true RS-232 performance from a 3.0V to 5.5V supply with a dual charge pump. The device is guaranteed to run at data rates of 250kbps while maintaining RS-232 output levels.
The ST3243 Auto-powerdown feature functions when FORCEON is low and FORCEOFF is high. During this mode of operation, if the device does not sense a valid RS-232 signal, the driver outputs are disabled. If FORCEOFF is set low, both drivers and receivers (expert R2B) are shut off, and supply current is reduced to 1mA. Disconnecting the serial port or turning off the peripheral drives causes the auto-powerdown condition to occur. Auto-powerdown can be disabled when FORCEON and FORCEOFF are high, and should be done when driving a serial mouse. With Auto-powerdown enabled, the device is activated automatically when a valid signal is applied to any receiver input.
ST3243 Typical application are in notebook, subnotebook, palmtop computers, battery-powered equipment, hand-held equipment, peripherals and printers.