PinoutSpecificationsDescriptionThe T-13806 is one kind of T1/CEPT interface transformer device (Reinforced Insulation Per EN 41003/EN 60950), T-13806 has three points of test conditions:(1)Tested @ 100 kHz and 100 mV (Pins 1-3); (2)Tested @ 100 kHz and 100 mV (Pins 1-3, short 5-8); (3)Tested @ 100...
T-13806: PinoutSpecificationsDescriptionThe T-13806 is one kind of T1/CEPT interface transformer device (Reinforced Insulation Per EN 41003/EN 60950), T-13806 has three points of test conditions:(1)Tested @ ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.


The T-13806 is one kind of T1/CEPT interface transformer device (Reinforced Insulation Per EN 41003/EN 60950), T-13806 has three points of test conditions:(1)Tested @ 100 kHz and 100 mV (Pins 1-3); (2)Tested @ 100 kHz and 100 mV (Pins 1-3, short 5-8); (3)Tested @ 100 kHz and 100 mV (Pins 1 & 5 to 3 & 8).
The electrical characteristics of the T-13806 can be summarized as:(1)Inductance: 7.3 Min. mH;(2)Leakage Inductance: 7.5 Max. uH;(3)Interwinding Capacitance (CW/W): 25 pF;(4)DCR Primary Pins 1-2 or 2-3: 1.1 ohms;(5)Secondary DC Resistance: 0.6 ohms;(6)Isolation (HI-POT): 1500 VRMS. If you want to know more information about the T-13806, please download the datasheet in www.seekic.com or www.chinaicmart.com .