H8S/2643 General Description
H8S/2643 Features
• Maximum 16-pulse input/output
A total of 16 timer general registers (TGRs) are provided (four each for channels 0 and 3,
and two each for channels 1, 2, 4, and 5), each of which can be set independently as an
output compare/input capture register
TGRC and TGRD for channels 0 and 3 can also be used as buffer registers
• Selection of 8 counter input clocks for each channel
• The following operations can be set for each channel
Waveform output at compare match: Selection of 0, 1, or toggle output
Input capture function: Selection of rising edge, falling edge, or both edge detection
Counter clear operation: Counter clearing possible by compare match or input capture
Synchronous operation: Multiple timer counters (TCNT) can be written to simultaneously
Simultaneous clearing by compare match and input capture possible
Register simultaneous input/output possible by counter synchronous operation
PWM mode: Any PWM output duty can be set
Maximum of 15-phase PWM output possible by combination with synchronous operation
• Buffer operation settable for channels 0 and 3
Input capture register double-buffering possible
Automatic rewriting of output compare register possible
• Phase counting mode settable independently for each of channels 1, 2, 4, and 5
Two-phase encoder pulse up/down-count possible
• Cascaded operation
Channel 2 (channel 5) input clock operates as 32-bit counter by setting channel 1 (channel 4) overflow/underflow
• Fast access via internal 16-bit bus
Fast access is possible via a 16-bit bus interface
• 26 interrupt sources
For channels 0 and 3, four compare match/input capture dual-function interrupts and one
overflow interrupt can be requested independently
For channels 1, 2, 4, and 5, two compare match/input capture dual-function interrupts, one overflow interrupt, and one underflow interrupt can be requested independently
• Automatic transfer of register data
Block transfer, 1-word data transfer, and 1-byte data transfer possible by data transfer controller (DTC) or DMA controller (DMAC)
• Programmable pulse generator (PPG) output trigger can be generated
Channel 0 to 3 compare match/input capture signals can be used as PPG output trigger
• A/D converter conversion start trigger can be generated
Channel 0 to 5 compare match A/input capture A signals can be used as A/D converter conversion start trigger
• Module stop mode can be set
As the initial setting, TPU operation is halted. Register access is enabled by exiting module stop mode.