UC3176 General Description
UC3176 Maximum Ratings
Input Supply voltage, (+VIN) . . . . . . . . . . . . . . . . . . .. 40V
Park/Inhibit, UV1 and UV2 inputs (zener clamped)
Maximum forced voltage . . . . . . . . . . . . . . . . -0.3V to 10V
Maximum forced current. . . . . . . . . . . . . . . . . . . .. ±10mA
Other Input Voltages. . . . . . . . . . . . . . . . . . -0.3V to +VIN
AlSINK and BlSINK Voltages . . . . . . . . . . . . . . -0.3V to 6V
Open Collector Output Voltages. . . . . . . . . . . . . . . . . 40V
A and B Output Currents (Continuous)
Source . . . . . . . . . . . . . . . . . . . . . . . . .. Internally Limited
Sink. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5A
Total Supply Current (Continuous). . . . . . . . . . . . . . . . 4A
Parking Drive Output Current (Continuous) . . . . . 200mA
Supply OK Output Current, UC3177 (Continuous) . 30mA
Operating Junction Temperature . . . . .-55°C to +150°C
Power Dissipation at TC = +75°C
QP package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4W
Storage Temperature . . . . . . . . . . . . . -65°C to +150°C
Note 1: Unless otherwise indicated, voltages are reference to ground and currents are positive into, negative out of, the specified terminals.
UC3176 Features
· Dual Power Operational Amplifiers
· ±2A Output Current Guaranteed
· Precision Current Sense Amplifier
· Two Supply Monitoring Inputs
· Parking Function and Under-Voltage Lockout
· Safe Operating Area Protection
· 3V to 35V Operation